Stainless steel bushfire woven wire mesh for ember protection
Bushfire Mesh Explaination
Many areas of Australia are subject to summer bushfires which cause loss of life, livestock, homes, farm buildings and infrastructure, and cost the country millions of dollars every year.
In Victoria in 2009, what became known as the Black Saturday bush fires, prompted the development of Australian Standard 3959-2009 (Construction of Buildings in Bushfire Prone Areas) which gives people who are building, re-building, retrofitting or renovating their homes, a clear direction on how to better protect their homes against bushfires.
Stainless steel woven wire mesh supplied in 30m rolls for use in protecting homes in bushfire prone areas. Both grade 304 and 316 stainless steel are avaliable.
Bushfire mesh can be used for protection against ember attack and radiant heat. It can be used to protect windows (inlcuding skylights), doors, decks and patios, evaporative cooling units, gable and roof vents, gutters, eaves and downpipes.
Radiant Heat & Ember Protection
The Australian Standard AS 3959-2009 ‘construction of building in bushfire-prone areas’ specifies screening of openings to be made with corrosion- resistant steel mesh, with a maximum aperture of 2mm
General Sizes:
Standard roll width 3ft - 5 ft
Standard roll length: 30m
Special size we can make it according to the clients’s request.
Our Service :
OEM | Yes |
Special Sizes or Shape | Yes |
Customized packing | Yes |
Sample | Can be offered or Made |
Delivery time | Usually within 7-15 working days |
Payment terms | T/T, Western Union, PayPal., Escrow, L/C |
Optional Way of Transportation | Sea Transportation, Air Transportation International Express: DHL,TNT,DEDEX,UPS,EMS |
Radiant Heat
Fire Test on attenuation of radiant heat flux
Using a test procedure given in AS 1530 part 8.1 the mesh has been evaluated using a radiant heat flux exposure of up to and including 40kW/m² (BAL 40). The attenuation of the radiant heat flux provided by the mesh was approximately 50%.
AS 3959 ember protection of openings ‘Construction of Buildings in Bushfire Prone Areas’ 2009
The mesh has been tested in accordance with this standard and complies with and meets the dimensional requirements of the standard as it has an aperture of less than 2mm.
Minimum Sale Quantities
Sold 30m roll only
915mm, 1220mm & 1245mm wide – 2 lineal meters
1550mm wide – 10 lineal meters (only sold in multiples of 10 lineal meters)
Quality contral:
* Certified with ISO 9001:2008 / CE / EN / SGS
* High-end produce with good quality , excellent in workmanship , best service
* All of the product are inspected carefully by QC before delivery
Contect Details :
Anping Yoston Metal Wire Mesh Co.,Ltd.
No.56 Yuhua South Road , Anping Hebei China
Tel / Wechat / Whatsapp: +86 15833839680
Email: yoston@foxmail.com
Skype: amyhdff
Attn: Amy